Oxygen Generator For Chemical Laboratory

Oxygen Generator For Chemical Laboratory
Product Introduction:
This PSA (Pressure Swing Adsorption) oxygen generator provides a reliable, continuous supply of high-purity oxygen (typically 93–99%) directly from ambient air—eliminating reliance on cylinder deliveries. Perfect for chemical labs, it supports analytical instruments, oxidation studies, aging tests, and other controlled experiments with precision and cost-efficiency.
Send Inquiry
Description
Technical Parameters
High-Purity, On-Demand Oxygen Tailored for Chemical Laboratories and Research
 

PSA Technology: Ambient air is compressed and passed through zeolite sieve beds, which adsorb nitrogen, allowing high-purity oxygen (~90–95%) to pass through in alternating adsorption/desorption cycles.

Purity Control: Adjustments to pressure and cycle times enable fine-tuning of oxygen purity to match specific laboratory needs.

Ultra-High Purity Options: Some advanced models deliver up to 99% purity with stable output and tight concentration controls (±0.2%).

Oxygen generator for chemical laboratory

Key Features & Benefits

Feature Laboratory Procurement Value Proposition
High Purity (93–99%) Supports sensitive analytical methods like GC, chemiluminescence, and oxidation experiments.
Tailored Flow Rates From small-scale lab use to pilot processes-select appropriate capacity to match your workloads. 
On-Demand Reliability Continuous generation ensures that experiments aren't interrupted by cylinder supply issues.
Cost Efficiency Eliminates recurring cylinder costs and delivery hassles; ROI often in 6–24 months.
Compact & Automated Minimal bench or floor space; automatic control systems with purity alarms enhance safety.
Safe & Low-Maintenance Reduced fire and handling risks vs. high-pressure cylinders; maintenance usually simple and low-cost.
Technical Specifications (Example Models)

 

Typical Lab PSA Generator

Flow Rate: 5–200 Nm³/h

Oxygen Purity: ~93% ±3%

Power Efficiency: Approx. 1.6–3.5 kW per Nm³/hr

Design Conditions: <500 m altitude, ≤80% RH, 0–38 °C

Operational Notes: Each unit covers filling ~10–200 cylinders per 12 hrs

 

Ultra-High Purity Model

Purity: 96–99% with ±0.2% stability

Flow: 2.6–90 Nm³/h

Features: Dual-stage separation, touchscreen UI, robust cabinet, stable output pressure

 

Mid-Range PSA Model

Purity & Flow Options: Up to ~95% purity; flows ranging 1.9 to 118 Nm³/h depending on model

Standard Features: Skid-mounted components, oxygen analyzer, PLC control, safety valves, buffer tanks (optional)

Target Laboratory Applications

 

Instrument Supply: Oxygen for GC carrier/reaction gas, chemiluminescence detectors-ensures trace-level accuracy.

Materials Testing: Controlled oxidation or aging of polymers, metals under oxygen-rich environments.

Pilot Chemistry: Oxidation reactions, including accelerated aging or combustion studies.

General Lab & QA/QC: Oxygen for box environments, gloveboxes, and standard lab use (flame tests, combustion).

 

Why Laboratory Procurement Favors This System

 

Stable Analytical Environments: Precise oxygen purity ensures reproducibility in chemical and material analysis.

Reduced Supplier Dependency: On-site generation alleviates risks from delivery delays or cylinder supply shortages.

Budget-Friendly Operation: Long-term savings on gas procurement and logistics.

Safety-first Design: Avoids high-pressure cylinder hazards and promotes cleaner lab areas.

Scalable & Flexible Design: Modular, with options for future capacity or purity scaling.

 

B2B Procurement Workflow
 

Submit Lab Requirements: Indicate required flow (Nm³/h), purity level, and operating conditions.

Receive Technical Proposal & Quote: You'll be offered model recommendations, detailed specs, pricing, and ROI analysis.

Sample Testing or Pilot Trial: Validate performance in your instruments or test setups.

Final Order & Installation: Includes onsite installation, commissioning, and training.

Operational Support: Ongoing maintenance, spare parts, consumables, and optional remote monitoring tools.

 

>>>FAQ

Q: What purity levels and flows are available?
A: Standard models deliver ~93% purity; advanced units achieve 96–99%. Flows typically range from 5 to 100 Nm³/h, and up to 90 for ultra-high purity systems.

 

Q: How economical is it vs. cylinder supply?
A: ROI typically occurs within 6–24 months by cutting recurring cylinder costs and eliminating delivery hassles.

 

Q: Is it safe and suitable for lab environments?
A: Yes. Fully automated, compact, and eliminates need for handling high-pressure cylinders-enhancing lab safety.

 

Q: Can purity be adjusted for different experiments?
A: Yes. Purity and flow can be customized via system settings or selecting multi-stage models.

 

Q: What instrumentation support is included?
A: Comes with analyzers, purity alarms, touchscreen PLC, buffer tanks, optional remote monitoring-all configurable per lab needs.

 

 

 

Hot Tags: oxygen generator for chemical laboratory, China oxygen generator for chemical laboratory manufacturers, suppliers, Industrial Oxygen Machine, PSA Oxygen Generator for Industrial Use, oxygene generator industrial, Industrial Oxygen Gas Plant, Oxygen Generator Industrial, industrial oxygen generator

Send Inquiry
Ready to see our solutions?

PSA Oxygen Plant

●What is the O2 capacity needed?
●What is O2 purity needed? standard is 93%+-3%
●What is O2 discharge pressure needed?
●What is the votalge and frequency in both 1Phase and 3Phase?
●What is the working site temeperature averagely?
●What is the humidity locally?

PSA Nitrogen Plant

●What is the N2 capacity needed?
●What is N2 purity needed?
●What is N2 discharge pressure needed?
●What is the votalge and frequency in both 1Phase and 3Phase?
●What is the working site temeperature averagely?
●What is the humidity locally?

Send Inquiry