NTK93 Series |
|||||
Models |
Capacity (Nm3/hr) |
Purity |
Power consumption of 1Nm3 oxygen produced (kw/h) |
Number of bottles filled in 12 hours (pcs) |
Operator needed |
NTK-5P | 5 | 93%+-3% | 3.54 | 10 | 2 |
NTK-10P | 10 | 93%+-3% | 2.52 | 20 | 2 |
NTK-15P | 15 | 93%+-3% | 2.31 | 30 | 2 |
NTK-20P | 20 | 93%+-3% | 2.13 | 40 | 2 |
NTK-25P | 25 | 93%+-3% | 2.01 | 50 | 2 |
NTK-30P | 30 | 93%+-3% | 2.09 | 60 | 2 |
NTK-40P | 40 | 93%+-3% | 1.81 | 80 | 2 |
NTK-50P | 50 | 93%+-3% | 1.94 | 100 | 2 |
NTK-60P | 60 | 93%+-3% | 1.62 | 120 | 2 |
NTK-80P | 80 | 93%+-3% | 1.92 | 160 | 2 |
NTK-100P | 100 | 93%+-3% | 1.83 | 200 | 2 |
Design basis: Altitude:≤500m;RH:≤80%;Temperature:0℃-38℃;Filling pressure: 150Bar 40L Type Standard Cylinder | |||||
Procurement service support
- OEM/ODM customization (color/LOGO/voltage adaptation)
- Tiered quotation for bulk purchases
- Wide range of global logistics options
- One-year free warranty
- Free on-site installation
Application areas
1. Hospital Intensive Care Unit (ICU/Oxygen Central Supply)
System Integration Solution
Use 10 units in parallel, monitor oxygen purity (93%±3%) in real time through the central console, and each unit is equipped with a modular design to ensure 24-hour uninterrupted oxygen supply.
▸ Core Function: Replace traditional liquid oxygen tanks, reduce the risk of oxygen transportation pollution, and ensure the safety of oxygen use for critically ill patients through an intelligent early warning system (automatically switch to the backup tower when the oxygen concentration is <90%).
2. Plateau Emergency Medical Treatment (4500 meters above sea level)
Technical Breakthrough
▸ Adopting an altitude compensation algorithm, it can still maintain 93% flow output in areas above 4000 meters, and is equipped with a dust-proof heat dissipation kit to adapt to low temperature and low oxygen environments.
FAQ
Q: What is the core difference between medical-grade PSA oxygen generators and traditional liquid oxygen tanks?
A: 1. Material safety: Use flow channel materials that pass European standards to eliminate the risk of heavy metal precipitation; 2. Oxygen supply stability: Modular equipment reduces oxygen supply fluctuations by 82% compared to liquid oxygen evaporation; 3. Hospital infection control: Closed oxygen generation avoids bacterial contamination caused by liquid oxygen transportation.
Q: What is the technical adaptation plan for equipment in plateau environments?
A: 1. Equipped with an altitude sensor to automatically adjust the adsorption cycle (0.3 seconds of adsorption time is compensated for every 1,000 meters of increase); 2. Use a scroll compressor to maintain 1.2MPa output under low atmospheric pressure; 3. Anti-condensation design prevents molecular sieves from getting wet.
Q: How to verify the medical-grade service life of molecular sieves?
A: Through three-stage verification: 1. Laboratory 5,000-hour continuous decay test (capacity decay rate <1.2%/1000h); 2. Clinical environment microbial detection (bacterial residue <10CFU/m³); 3. Plateau/high humidity extreme environment pressure test.
Q: How does the device meet the medical compliance requirements of different countries?
A: Configure the intelligent compliance module: 1. Switchable oxygen concentration standards; 2. Interface compatibility: Supports American standard DISSS connector/European standard ENISO 9170-1 interface.
Hot Tags: medical grade psa oxygen generator, China medical grade psa oxygen generator manufacturers, suppliers, pressure swing adsorption oxygen plant, o2 generation plant, containerized gaseous nitrogen generator, PSA Modular Oxygen Generation Plant, Twin Tower PSA Oxygen Generators, psa nitrogen plant